Search results for "Emission computed tomography"

showing 10 items of 46 documents

Evaluation of Mucociliary Clearance by Three Dimension Micro-CT-SPECT in Guinea Pig: Role of Bitter Taste Agonists

2016

Different image techniques have been used to analyze mucociliary clearance (MCC) in humans, but current small animal MCC analysis using in vivo imaging has not been well defined. Bitter taste receptor (T2R) agonists increase ciliary beat frequency (CBF) and cause bronchodilation but their effects in vivo are not well understood. This work analyzes in vivo nasal and bronchial MCC in guinea pig animals using three dimension (3D) microCT-SPECT images and evaluates the effect of T2R agonists. Intranasal macroaggreggates of albumin-Technetium 99 metastable (MAA-Tc99m) and lung nebulized Tc99m albumin nanocolloids were used to analyze the effect of T2R agonists on nasal and bronchial MCC respecti…

0301 basic medicinePathologyPhysiologyRespiratory Systemlcsh:MedicineSingle Photon Emission Computed TomographyPharmacologyBiochemistryDiagnostic RadiologyReceptors G-Protein-CoupledMathematical and Statistical Techniques0302 clinical medicineBronchodilationMedicine and Health Scienceslcsh:ScienceTomographyLungMammalsMultidisciplinaryRadiology and ImagingDrugsfood and beveragesChloroquineAnimal Modelsrespiratory systemPulmonary ImagingBody Fluidsmedicine.anatomical_structureMucociliary ClearanceVertebratesPhysical SciencesAnatomyStatistics (Mathematics)Research ArticleAgonistmedicine.medical_specialtySingle Photon Emission Computed Tomography Computed TomographyImaging TechniquesMucociliary clearancemedicine.drug_classGuinea PigsBronchiNeuroimagingResearch and Analysis MethodsRodentsGuinea pigAntimalarials03 medical and health sciencesModel OrganismsDiagnostic MedicineIn vivoAlbuminsmedicineAnimalsHumansStatistical MethodsPharmacologyAnalysis of VarianceLungbusiness.industrylcsh:ROrganismsBiology and Life SciencesProteinsX-Ray MicrotomographyMucus030104 developmental biology030228 respiratory systemAmniotesNanoparticleslcsh:QNasal administrationbusinessMathematicsEx vivoNeuroscience
researchProduct

Drug Distribution to Retinal Pigment Epithelium: Studies on Melanin Binding, Cellular Kinetics, and Single Photon Emission Computed Tomography/Comput…

2016

Melanin binding is known to affect the distribution and elimination of ocular drugs. The purpose of this study was to evaluate if the extent of drug uptake to primary retinal pigment epithelial (RPE) cells could be estimated based on in vitro binding studies with isolated melanin and evaluate the suitability of single photon emission computed tomography/computed tomography (SPECT/CT) in studying pigment binding in vivo with pigmented and albino rats. Binding of five compounds, basic molecules timolol, chloroquine, and nadolol and acidic molecules methotrexate and 5(6)-carboxy-2',7'-dichlorofluorescein (CDCF), was studied using isolated melanin from porcine choroid-RPE at pH 5.0 and 7.4. The…

0301 basic medicinePathologymedicine.medical_specialtySingle Photon Emission Computed Tomography Computed TomographySwinePigment bindingPharmaceutical ScienceTimololRetinal Pigment EpitheliumBiologySingle-photon emission computed tomographyEye030226 pharmacology & pharmacyIodine RadioisotopesMelanin03 medical and health scienceschemistry.chemical_compound0302 clinical medicineIn vivoDrug DiscoverymedicineAnimalsDistribution (pharmacology)Cells CulturedMelaninsRetinal pigment epitheliummedicine.diagnostic_testChloroquineRetinalHydrogen-Ion Concentrationeye diseasesRats3. Good healthKineticsNadololMethotrexate030104 developmental biologymedicine.anatomical_structurechemistryTimololBiophysicsMolecular Medicinesense organsProtein Bindingmedicine.drugMolecular Pharmaceutics
researchProduct

Comparison Study of Two Differently Clicked 18F-Folates—Lipophilicity Plays a Key Role

2018

Within the last decade, several folate-based radiopharmaceuticals for Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been evaluated; however, there is still a lack of suitable 18F-folates for clinical PET imaging. Herein, we report the synthesis and evaluation of two novel 18F-folates employing strain-promoted and copper-catalyzed click chemistry. Furthermore, the influence of both click-methods on lipophilicity and pharmacokinetics of the 18F-folates was investigated. 18F-Ala-folate and 18F-DBCO-folate were both stable in human serum albumin. In vitro studies proved their high affinity to the folate receptor (FR). The lipophilic character of …

0301 basic medicinePharmaceutical Sciencelcsh:Medicinelcsh:RS1-441copper-catalyzed clickSingle-photon emission computed tomographyArticlelcsh:Pharmacy and materia medica03 medical and health sciencesfolic acid0302 clinical medicinePharmacokineticsIn vivoDrug Discoverymedicinemedicine.diagnostic_testChemistrylcsh:Rstrain promoted clickHuman serum albumin<sup>18</sup>F-folates; PET; folic acid; folate receptor; click chemistry; copper-catalyzed click; strain promoted click18F-folatesfolate receptor030104 developmental biologyPETPositron emission tomographyFolate receptor030220 oncology & carcinogenesisLipophilicityclick chemistryClick chemistryBiophysicsMolecular Medicinemedicine.drugPharmaceuticals
researchProduct

Contribution of thallium-201-SPECT to the grading of tumorous alterations of the brain

1992

Single photon emission computed tomography (SPECT) with thallium-201-chloride (201Tl) was used in 22 patients to assess the grade of malignancy of brain tumors. Low- and high-grade malignant gliomas could be well differentiated by calculating the Grade Index (GI), i.e., 201Tl uptake in the tumor area relative to a contralateral brain region. Low-grade gliomas (WHO-grade I-II) usually showed a GI of1.5. Tumors classified histologically as high-grade malignant (WHO-grade III-IV) had GI values greater than 1.42 and a mean value of 1.89. Until labelled amino-acid tracers for gamma-cameras become commercially available, thallium-201 brain-SPECT can provide an independent and complementary method…

AdenomaAdultMalemedicine.medical_specialtychemistry.chemical_elementAstrocytomaSingle-photon emission computed tomographyMalignancyDiagnosis DifferentialMeningeal NeoplasmsmedicineHumansPituitary NeoplasmsGrading (tumors)AgedNeoplasm StagingTomography Emission-Computed Single-Photonmedicine.diagnostic_testBrain Neoplasmsbusiness.industryBrainGliomaNeuroma AcousticGeneral MedicineMiddle Agedmedicine.diseaseThallium RadioisotopeschemistryPositron emission tomographyThalliumFemaleSurgeryNeurology (clinical)NeurosurgeryMeningiomabusinessNuclear medicineNeurosurgical Review
researchProduct

Dynamic image denoising for voxel-wise quantification with Statistical Parametric Mapping in molecular neuroimaging.

2018

Purpose PET and SPECT voxel kinetics are highly noised. To our knowledge, no study has determined the effect of denoising on the ability to detect differences in binding at the voxel level using Statistical Parametric Mapping (SPM). Methods In the present study, groups of subject-images with a 10%- and 20%- difference in binding of [123I]iomazenil (IMZ) were simulated. They were denoised with Factor Analysis (FA). Parametric images of binding potential (BPND) were produced with the simplified reference tissue model (SRTM) and the Logan non-invasive graphical analysis (LNIGA) and analyzed using SPM to detect group differences. FA was also applied to [123I]IMZ and [11C]flumazenil (FMZ) clinic…

AdultFlumazenilMalelcsh:MedicineNeuroimagingSingle-photon emission computed tomographycomputer.software_genreStatistical parametric mapping030218 nuclear medicine & medical imaging03 medical and health sciencesddc:616.89Young Adult0302 clinical medicineNeuroimagingVoxelPositron Emission Tomography Computed TomographymedicineHumanslcsh:ScienceMathematicsParametric statisticsTomography Emission-Computed Single-PhotonIomazenilMultidisciplinarymedicine.diagnostic_testbusiness.industrylcsh:RBinding potentialPattern recognitionPositron emission tomographylcsh:QArtificial intelligencebusinesscomputer030217 neurology & neurosurgeryAlgorithmsPloS one
researchProduct

Somatostatin-receptor scintigraphy in Graves' disease: reproducibility and variance of orbital activity.

2000

Somatostatin-receptor (SSTR) scintigraphy using the single photon emission computed tomography (SPECT) technique allows the assessment of orbital inflammation in patients with Graves' disease. Previous studies showed differences in orbital octreotide uptake already 4 hr after injection. In this study, analysis of inter-/intra-observer variance and reproducibility in the evaluation of orbital SPECT images was performed. First, SPECT data of one representative female patient with clinically active Graves' ophthalmopathy (GO), obtained 4 hr after intravenous injection of 110 MBq 111In-pentetreotide and processed by filtered backprojection, were analyzed. Transverse SPECT images were reconstruc…

AdultMaleCancer ResearchGraves' diseaseSingle-photon emission computed tomographyScintigraphyCorrelationSpearman–Brown prediction formulamedicineHumansRadiology Nuclear Medicine and imagingAgedPharmacologyObserver VariationTomography Emission-Computed Single-PhotonReproducibilitymedicine.diagnostic_testbusiness.industryIndium RadioisotopesReproducibility of ResultsGeneral MedicineVariance (accounting)Middle Agedmedicine.diseaseGraves DiseaseOncologyFemaleTomographybusinessNuclear medicineSomatostatinOrbitCancer biotherapyradiopharmaceuticals
researchProduct

Die nächste Generation „atypischer” Antipsychotika: Der Beitrag der Positronenemissionstomographie

2003

Almost fifteen years of research with Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) have led to a profound understanding of the relationships between antipsychotic doses and plasma levels on the one hand and occupancy of (striatal) D 2 -like dopamine receptors on the other hand as well as with the associated clinical effects and side effects. Furthermore, with the development of clinically atypical" antipsychotics PET studies helped to generate hypotheses regarding the essential pharmacological properties of this heterogeneous class of drugs. Possible mechanisms of action include combined D 2 -/5-HT 2 antagonism, preferential mesolimbic binding, a…

Agonistmedicine.medical_specialtymedicine.diagnostic_testmedicine.drug_classmedicine.medical_treatmentSingle-photon emission computed tomographyPsychiatry and Mental healthEndocrinologyNeurologyMechanism of actionPositron emission tomographyDopamine receptorIn vivoInternal medicinemedicineAripiprazoleNeurology (clinical)medicine.symptomPsychologyAntipsychoticmedicine.drugFortschritte der Neurologie · Psychiatrie
researchProduct

Beta Decay Studies of Neutron Rich Nuclei Using Total Absorption Gamma-ray Spectroscopy and Delayed Neutron Measurements

2010

International audience; A complete characterisation of the β-decay of neutron-rich nuclei can be obtained from the measurement of β-delayed gamma rays and, whenever the process is energetically possible, β-delayed neutrons. The accurate determination of the β-intensity distribution and the β-delayed neutron emission probability is of great relevance in the fields of reactor technology and nuclear astrophysics. A programme for combined measurements using the total absorption gamma-ray spectroscopy technique and both neutron counters and neutron time-of-flight spectrometers is presented.

Astrofísica nuclearNeutron emissionAstrophysics::High Energy Astrophysical PhenomenaNuclear TheoryGeneral Physics and AstronomyBeta decayNeutron scattering[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesNuclear physicsPrompt neutronNuclear Technology0103 physical sciencesNuclear AstrophysicsNeutron cross sectionNeutronDelayed neutrons emission010306 general physicsNuclear ExperimentSpectroscopyPhysics:Energies::Energia nuclear [Àrees temàtiques de la UPC]Total Absorption Gamma-Rayta114010308 nuclear & particles physicsRadioactivitat betaNeutron stimulated emission computed tomographyBeta DecayDelayed Neutron Emission3. Good healthNeutron Detectors23.40.Bw 29.30.KvNuclear astrophysicsPrompt neutronsDelayed neutronNeutron activation
researchProduct

Safety and feasibility of atropine added in patients with sub-maximal heart rate during exercise myocardial perfusion SPECT.

2006

Failure to reach 80% of maximal predicted heart rate (HR) during exercise may render a myocardial perfusion single photon emission computed tomography (SPECT) study non-diagnostic for ischemia detection. We sought to investigate the injection of atropine in patients who fail to achieve 80% of age-predicted HR during exercise performed for myocardial perfusion SPECT (MPS), defining its safety and efficacy to raise HR to adequate levels as well as its effect on MPS interpretation.Between January 2002 and December 2004, we studied 3,150 consecutive patients (2,253 men and 897 women, mean age 55 +/- 6 years) who were referred to a single office-based nuclear cardiology laboratory for MPS using …

AtropineMalemedicine.medical_specialtyIschemiaMyocardial IschemiaBlood PressureSingle-photon emission computed tomographySeverity of Illness IndexMetabolic equivalentCholinergic AntagonistsOrganophosphorus CompoundsHeart RateInternal medicineSpect imagingCoronary CirculationHeart rateMedicineHumansRadiology Nuclear Medicine and imagingTomography Emission-Computed Single-Photonexercise testingmedicine.diagnostic_testmaximal predicted heart ratebusiness.industrymyocardial perfusion SPECTArrhythmias CardiacOrganotechnetium CompoundsMiddle Agedmedicine.diseaseAtropineRate pressure productResearch DesignCardiologyExercise TestFeasibility StudiesFemaleRadiopharmaceuticalsCardiology and Cardiovascular MedicinebusinessPerfusionmedicine.drugThe international journal of cardiovascular imaging
researchProduct

Algorithms for Image Reconstruction

2010

Three-dimensional (3D) imaging is becoming one of the most important applications of radioactive materials in medicine. It offers good spatial resolution, a 3D insight into the human body, and a high sensitivity in the picomolar range because markers for biological processes can be detected well when labeled with radioactive materials. In addition, the technical equipment has undergone many technological achievements. This is true for single-photon emission computed tomography (SPECT), positron emission tomography (PET), and X-ray computed tomography (CT), which is often used in connection with the nuclear medical imaging systems, as also described in chapter 5 about sources in nuclear medi…

Data setmedicine.diagnostic_testPositron emission tomographyComputer sciencemedicineMedical imagingIterative reconstructionSensitivity (control systems)AlgorithmImage resolutionEmission computed tomographyFeature detection (computer vision)
researchProduct